Provisions the documents cite: 9.1.10 (viewing in daylight from 2 m, no artificial light on the surface); 9.5.3, 9.5.4, 9.5.5, 9.5.7, 9.5.10 (materials, conditions, timber and coats, surfaces, finished quality)
What it requires
The warranty standard for new homes. 9.1.10 sets the viewing rule for finishes; 9.5 sets materials storage, conditions (no condensation, cold surfaces), timber at 18 % maximum with primer + undercoat + finish within a month of each other, sound surfaces, minimum two coats, and the finished quality — evenly applied, no conspicuous runs or brush marks, background not visible.
How this entry is kept current
- Citation status: checked against the source on the date shown.
- Watched by: check the current edition each scan; chapter numbering can move between editions.
- Automated scan: no public page to watch; checked by hand in the monthly review.
Every source is re-checked monthly and the result is published in the scan log. A change that alters what a document should say raises a revision, and past buyers of that document are told.
The 139 documents that cite it
Every KubitDocs document prints its statutory basis on the form itself, so the person signing can verify the citation rather than take our word for it.
Bricklaying and masonry quality checklists
- Bond, Plumb, Line, Joints and Movement Joints — Quality Inspection Checklist
- Brick Slips and Brick-Faced Panels — Quality Inspection Checklist
- Cavity Wall — Ties, Insulation, Trays, Weeps and Closers — Quality Inspection Checklist
- Internal Blockwork — Fire and Acoustic Walls — Quality Inspection Checklist
- Lintels, Bearings and Restraints — Quality Inspection Checklist
- Setting Out, DPC and First Lifts — Quality Inspection Checklist
- Stone Masonry, Cast Stone and Restoration — Quality Inspection Checklist
Carpentry and joinery first fix quality checklists
- Floor Joists, Strutting and Notching — Quality Inspection Checklist
- Roof Carcass and Trusses — Bracing and Restraint Straps — Quality Inspection Checklist
- Stud Walls and Door Linings — First Fix — Quality Inspection Checklist
- Timber Moisture and Treatment Record — Quality Inspection Checklist
Cladding and façades quality checklists
- Built-Up and Composite Metal Cladding — Liner, Spacer, Insulation, Outer Sheet and Fasteners — Quality Inspection Checklist
- Copings, Cappings, Soffits and Louvres — Quality Inspection Checklist
- Curtain Walling and Structural Glazing — Quality Inspection Checklist
- Insulation, Cavity Barriers and Fire-Stopping in the Cavity — Quality Inspection Checklist
- Panel Installation — Rainscreen, Composite and Timber — Quality Inspection Checklist
- SFS Infill Walls and Sheathing Board — Frame, Fixings and Sheathing Before the Membrane — Quality Inspection Checklist
- Sealing, Interfaces and Water Testing — Quality Inspection Checklist
- Setting Out, Brackets and Rails — Quality Inspection Checklist
- Unitised Curtain Walling — Units, Hooking-On, Stack Joints and Closure — Quality Inspection Checklist
Close-out records
- Defects-Period Inspection — Record
- Pest Control and Final Clean at Handover — Record
- Pre-Handover Inspection — Client Walk — Record
- Snagging and De-Snagging — Room by Room — Record
Decoration quality checklists
- Anti-Carbonation Coatings to Concrete — Quality Inspection Checklist
- Asbestos-Suspect Textured Coatings — Check and Stop Record
- Breathable Coatings to Traditional and Heritage Substrates — Quality Inspection Checklist
- Clear Finishes to Timber — Quality Inspection Checklist
- Colour and Batch Schedule
- Damp, Salts and Biological Growth — Diagnosis Before Coating
- Decoration Package — ITP Cover Sheet
- Dry-Lined and Jointed Boards — Quality Inspection Checklist
- External Ferrous Metalwork Painting — Quality Inspection Checklist
- External Joinery Painting — Quality Inspection Checklist
- External Spray Application — Quality Inspection Checklist
- Fire Doors and Frames Decoration — Quality Inspection Checklist
- Fire-Retardant Coatings to Timber and Boards — Quality Inspection Checklist
- Fitted Furniture and Panelling Finishes — Quality Inspection Checklist
- Floor Paints and Coatings — Quality Inspection Checklist
- Galvanised, Aluminium and uPVC Surfaces — Quality Inspection Checklist
- Hygienic Wall Coatings — Quality Inspection Checklist
- Internal Decoration — Quality Inspection Checklist
- Internal Line Marking and Floor Signage — Quality Inspection Checklist
- Intumescent Coatings to Structural Steel — Quality Inspection Checklist
- Lead Paint — Survey, Removal and Clearance — Quality Inspection Checklist
- Masonry Paint to External Walls — Quality Inspection Checklist
- New Joinery Painting — Quality Inspection Checklist
- Performance Coatings — Anti-Graffiti and Anti-Microbial — Quality Inspection Checklist
- Playground and Sports Surface Markings — Quality Inspection Checklist
- Radiators and Internal Metalwork Painting — Quality Inspection Checklist
- Redecoration of Existing Surfaces — Quality Inspection Checklist
- Redecoration of External Render and Masonry — Quality Inspection Checklist
- Redecoration of Joinery and Doors — Quality Inspection Checklist
- Spray Application Internal — Quality Inspection Checklist
- Staircases, Handrails and Balustrades Decoration — Quality Inspection Checklist
- Textured and Acoustic Ceilings — Quality Inspection Checklist
- Timber Cladding and Decking Finishes — Quality Inspection Checklist
- Wallcoverings — Quality Inspection Checklist
Fitted furniture and FF&E quality checklists
- Blinds, Curtains and Tracks — Quality Inspection Checklist
- Fitted Furniture and Joinery Units — Quality Inspection Checklist
- IPS Panels, Cubicles and Lockers — Quality Inspection Checklist
- Loose Furniture and Equipment — Quality Inspection Checklist
- Racking, Mezzanines and Storage — Quality Inspection Checklist
- Signage and Wayfinding — Quality Inspection Checklist
- Wall Protection and Handrails — Quality Inspection Checklist
Flooring and tiling quality checklists
- Carpet and Carpet Tiles — Quality Inspection Checklist
- Entrance Matting and Thresholds — Quality Inspection Checklist
- Floor Substrate Acceptance — Quality Inspection Checklist
- Resin, Terrazzo and Specialist Floors — Quality Inspection Checklist
- Timber and Engineered Flooring — Quality Inspection Checklist
- Vinyl and Safety Flooring — Quality Inspection Checklist
- Wall and Floor Tiling — Quality Inspection Checklist
Glazing and windows quality checklists
- Glazing — Glass Specification, Marks, Drainage and Beads — Quality Inspection Checklist
- Opening Preparation, DPCs and Cavity Closers — Quality Inspection Checklist
- Window Films, Manifestation and Adjustment — Quality Inspection Checklist
- Window and Door Frame Installation — Fixings, Packers and Sealing — Quality Inspection Checklist
Groundworks and civils quality checklists
- Backfill and Compaction — Quality Inspection Checklist
- Below-Ground Drainage — Quality Inspection Checklist
- Below-Ground Services and Ducts — Quality Inspection Checklist
- Drainage Testing and CCTV — Quality Inspection Checklist
- Excavation and Formation — Quality Inspection Checklist
- Foundations — Trench and Pad — Quality Inspection Checklist
- Ground Gas and Radon Protection — Membrane, Venting and Verification — Quality Inspection Checklist
- Ground-Floor Slab and DPM — Quality Inspection Checklist
- Interceptors, Separators, Pumping Stations and Below-Ground Tanks — Quality Inspection Checklist
- Manholes and Inspection Chambers — Bases, Benching, Rings, Steps and Covers — Quality Inspection Checklist
- Setting Out and Levels — Quality Inspection Checklist
- SuDS — Attenuation Tanks, Crates, Soakaways and Permeable Sub-Base — Quality Inspection Checklist
Inspection and test plans
Insulation and airtightness quality checklists
- Acoustic Works — Floors and Seals — Quality Inspection Checklist
- Air Barrier — Laps and Penetrations — Quality Inspection Checklist
- Thermal Insulation — Continuity — Quality Inspection Checklist
Piling and substructure quality checklists
- Pile Caps and Ground Beams — Quality Inspection Checklist
- Pile Cut-Off and Integrity Testing — Quality Inspection Checklist
- Pile Installation Record — Quality Inspection Checklist
- Pile Setting Out and Working Platform — Quality Inspection Checklist
- Underpinning — Quality Inspection Checklist
Plastering and drylining quality checklists
- Boarding — Layers and Fixings — Quality Inspection Checklist
- Dry Lining on Dabs — Quality Inspection Checklist
- Fire-Stopping at Heads and Services — Quality Inspection Checklist
- Insulation and Acoustic Infill — Quality Inspection Checklist
- Metal Framing and Deflection Heads — Quality Inspection Checklist
- Services in the Wall and Pattresses — Quality Inspection Checklist
- Skim and Float — Flatness — Quality Inspection Checklist
- Taping, Jointing and Finish Level — Quality Inspection Checklist
Precast, timber frame and MMC quality checklists
- Precast Delivery, Bearings and Fixings — Quality Inspection Checklist
- SIPs and CLT Panels — Quality Inspection Checklist
- Timber Frame Erection — Sole Plates, Holding-Down and Breather Membrane — Quality Inspection Checklist
- Volumetric Modules and Pod Placement — Quality Inspection Checklist
Render and external finishes quality checklists
- External Wall Insulation — Fixings, Fire Barriers and Base Coat — Quality Inspection Checklist
- Lime Render — Traditional and Heritage Walls — Quality Inspection Checklist
- Render Coats, Curing and Finish — Quality Inspection Checklist
- Render Repair and Re-Rendering of Existing Walls — Survey, Removal, Making Good and New Coats — Quality Inspection Checklist
- Substrate, Beads and Mesh — Quality Inspection Checklist
Roofing quality checklists
- Flashings, Abutments and Lead Work — Quality Inspection Checklist
- Flat Roof — Insulation, Membrane, Laps, Upstands and Outlets — Quality Inspection Checklist
- Green and Blue Roof Build-Up — Quality Inspection Checklist
- Gutters, Rainwater Outlets and Overflows — Quality Inspection Checklist
- Liquid-Applied Roof Coatings — Quality Inspection Checklist
- Metal Standing Seam and Profiled Metal Roofing — Halters, Seams, Expansion and Terminations — Quality Inspection Checklist
- Pitched Roof — Underlay, Battens, Tiles and Fixings — Quality Inspection Checklist
- Reinforced Bitumen Membranes — Built-Up Felt Roofing — Quality Inspection Checklist
- Roof Deck and Vapour Control Layer — Quality Inspection Checklist
- Rooflights, Vents and Penetrations — Quality Inspection Checklist
- Single-Ply Membrane — Fastening Pattern, Welds and Peel Tests — Quality Inspection Checklist
- Terraces and Balconies — Membrane, Drainage, Pedestals, Thresholds and Balustrade Fixings — Quality Inspection Checklist
Screed quality checklists
- Levelling Compounds and Preparation — Quality Inspection Checklist
- Screed Moisture and Cure — Quality Inspection Checklist
- Screed — Substrate, DPM, UFH, Levels — Quality Inspection Checklist
Second-fix joinery quality checklists
- Doors, Frames and Ironmongery — Quality Inspection Checklist
- Fire Doors — Installation — Quality Inspection Checklist
- Kitchens and Worktops — Quality Inspection Checklist
- Skirtings, Architraves and Trims — Quality Inspection Checklist
- Timber Staircases and Balustrades — Quality Inspection Checklist
Waterproofing and tanking quality checklists
- Integrity Test and Protection Before Backfill — Quality Inspection Checklist
- Membrane Laps, Details and Penetrations — Quality Inspection Checklist
- Substrate Acceptance for Membranes — Quality Inspection Checklist
- Type B Integral Waterproofing — Waterbars, Kickers, Construction Joints and Crack Control — Quality Inspection Checklist
- Type C Cavity Drainage Membrane — Membrane, Channels, Sumps and Pumps — Quality Inspection Checklist