Provisions the documents cite: reg 7 (materials and workmanship); regs 16(4) and 17 (notice of completion, completion certificates); reg 38 (fire safety information); regs 39 and 40 (information about ventilation, fuel and power); regs 42 and 43 (ventilation air-flow and pressure testing, dwellings); reg 44 (commissioning notice)
What it requires
TG20:21 tube-and-fitting design/compliance; TG30:24 system scaffolds (updated May 2026, birdcage configurations); SG4:22 preventing falls in scaffolding operations. NASC guidance binds NASC members — it is not law.
The instrument itself: https://nasc.org.uk/. The summary above is our plain-English reading, not the text of the instrument — always work from the source.
How this entry is kept current
- Citation status: checked against the source on the date shown.
- Watched by: check for amendment, withdrawal or a new edition at each monthly horizon scan.
- Source last checked by the automated scan: 2026-09-01.
Every source is re-checked monthly and the result is published in the scan log. A change that alters what a document should say raises a revision, and past buyers of that document are told.
The 82 documents that cite it
Every KubitDocs document prints its statutory basis on the form itself, so the person signing can verify the citation rather than take our word for it.
Access and lifting inspection checklists
- Hoists — Erection, Tie-In and Inspection — Quality Inspection Checklist
- Lifting Equipment — Thorough Examination and Lift Plan Check — Quality Inspection Checklist
- Rope Access and Specialist Access — Daily Record — Quality Inspection Checklist
- Scaffold Handover and Weekly Inspection — Quality Inspection Checklist
Bricklaying & Masonry topic RAMS
Core permits
Demolition and strip-out quality checklists
- Pre-Strip Survey and Services Isolation — Quality Inspection Checklist
- Salvage, Retained Items and Protection — Quality Inspection Checklist
- Strip-Out Complete — Area Handover — Quality Inspection Checklist
- Structural Protection and Propping in Place — Quality Inspection Checklist
External Works & Landscaping RAMS
- Car Park Surfacing and Line Marking
- Fencing and Hoarding Erection
- Soft Landscaping and Planting
- Street Furniture and Signage Installation
- Tree Works Interface
External Works & Landscaping topic RAMS
External works and landscaping quality checklists
- Asphalt and Macadam Surfacing — Quality Inspection Checklist
- Car Park and Road Line Marking — Quality Inspection Checklist
- Fencing, Gates and Barriers — Quality Inspection Checklist
- Ironwork in Paved Surfaces — Covers, Gullies, Frames and Levels — Quality Inspection Checklist
- Kerbs, Edgings and Sub-Base — Quality Inspection Checklist
- Lighting Columns, Feeder Pillars and External Ducts — Foundations, Ducts and Alignment — Quality Inspection Checklist
- Paving, Tactiles and Accessible Gradients — Quality Inspection Checklist
- Playground and Sports Surfaces and Markings — Quality Inspection Checklist
- Resin-Bound and Resin-Bonded Surfacing — Quality Inspection Checklist
- Soft Landscaping — Soils, Planting, Tree Pits and Irrigation — Quality Inspection Checklist
- Street Furniture, Bollards, Cycle Stands and Signs — Foundations and Fixing — Quality Inspection Checklist
Groundworks & Civils RAMS
- Compaction, Hardcore and Sub-Bases
- Drainage Installation and Connections
- Excavation and Trenching
- Foundations and Pile Caps
- Kerbing, Paving and Slabbing
- Reduced-Dig and Contaminated Ground
- Service Trenches and Ducting
Groundworks & Civils topic RAMS
Groundworks and civils quality checklists
- Backfill and Compaction — Quality Inspection Checklist
- Below-Ground Drainage — Quality Inspection Checklist
- Below-Ground Services and Ducts — Quality Inspection Checklist
- Drainage Testing and CCTV — Quality Inspection Checklist
- Excavation and Formation — Quality Inspection Checklist
- Foundations — Trench and Pad — Quality Inspection Checklist
- Ground Gas and Radon Protection — Membrane, Venting and Verification — Quality Inspection Checklist
- Ground-Floor Slab and DPM — Quality Inspection Checklist
- Interceptors, Separators, Pumping Stations and Below-Ground Tanks — Quality Inspection Checklist
- Manholes and Inspection Chambers — Bases, Benching, Rings, Steps and Covers — Quality Inspection Checklist
- Setting Out and Levels — Quality Inspection Checklist
- SuDS — Attenuation Tanks, Crates, Soakaways and Permeable Sub-Base — Quality Inspection Checklist
Lifting operations
Lightning Protection & Signage RAMS
- Lightning Protection Installation and Testing
- Sign Installation — Illuminated
- Sign Installation — Non-Illuminated
Piling & Substructure RAMS
- Bored and CFA Piling
- Dewatering and Groundwater Control
- Driven and Preformed Piling
- Retaining Structures and Ground Anchors
- Underpinning
Piling and substructure quality checklists
- Pile Caps and Ground Beams — Quality Inspection Checklist
- Pile Cut-Off and Integrity Testing — Quality Inspection Checklist
- Pile Installation Record — Quality Inspection Checklist
- Pile Setting Out and Working Platform — Quality Inspection Checklist
- Underpinning — Quality Inspection Checklist
Plant & Lifting RAMS
Plant & Lifting topic RAMS
Safe systems of work
Scaffolding & Access RAMS
- Edge Protection Installation
- Loading Bays and Gantries
- Mobile Tower Assembly and Use
- System Scaffold — Erection and Dismantle
- Temporary Roof Installation
- Tube and Fitting Scaffold — Erection, Alteration, Dismantle
Scaffolding & Access topic RAMS
- Cantilever, Truss-Out and Hung Scaffolds
- Loading Materials onto Scaffold Lifts
- Rescue of Casualties from Scaffolds
- Scaffold Alterations While in Use
- Scaffolding Work in High Winds, Storms and Ice